آخر الأخبار

جاري التحميل ...

  1. For Electrical Engineering Information and Interview Questions

    visit

    Electrical Engineering Info

    Like my fb page https://www.facebook.com/electricalengineeringinfo

    ReplyDelete
  2. best robotic vacuum utilizes a infrared receiver and a contact-sensitive bumper to find its way around the home. The 'virtual walls' can be used to stop the robot from cleaning certain areas

    ReplyDelete
  3. This comment has been removed by the author.

    ReplyDelete
  4. This information is meaningful and magnificent which you have shared here about the Vacuum circuit breaker. I am impressed by the details that you have shared in this post and It reveals how nicely you understand this subject. I would like to thanks for sharing this article here. Test And Tag Melbourne

    ReplyDelete
  5. Your post is very nice. Vacuum Circuit Breakers (VCB) is must be carefully operation because Its supply high voltage.

    ReplyDelete

Merits and Demerits of Vacuum Circuit Breaker

5. Description of different Circuit Breaker
5.5 Vacuum circuit breaker
5.5.4 Merits of Vacuum Circuit Breakers
       The vacuum switchgear has been successfully developed and is gaining rapid popularity. The vacuum switches are likely to be popular for wide range of applications. These switches devices have several merits such as :
  1.  VCB is self contained  and does not need filling of gas or oil. They do not need auxiliary air system, oil handling system, etc. No need for periodic refilling.
  2. No emission of gases, pollution free.
  3. Modest maintenance of the breaker, no maintenance of interrupters. Hence economical over long period.
  4. Breakers forms a unit which can be installed at any required orientation. Breaker unit is compact and self contained.
  5. Non-explosive
  6. Silent operation.
  7. Large number of operation on load, or short circuit. Suitable for repeated duty.
  8. Long life of the order of several hundred operations on rated normal current.
  9. Constant dielectric. There are no gas decomposition products in vacuum and the hermetically sealed vacuum interrupter keeps out all environmental effect.
  10. Constant contact resistance. In vacuum, the contacts cannot be oxidized, a fact which ensures that their very small resistance is maintained through their life.
  11. High total current switched. Since contact piece erosion is small, rated normal interrupted current is up to 30.000 times; and rated short circuit breaking current is on the average of a hundred times.
       The above reasons, together with the economic advantages offered, have boosted acceptance  of the vacuum arc quenching principle.

5.5.5  Demerits of Vacuum Circuit Breakers
  1.  The vacuum interrupter is more expensive than the interrupter devices in other types of interrupters and its cost is affected by production volume. It is uneconomical to manufacturer vacuum interrupters in small quantities.
  2. Rated voltage of single interrupter is limited until very recently to about 36√3 = 20 KV above 36 KV, tow interrupters are required to be connected in series. This makes the breaker uneconomical for voltage rated above 36 KV.
  3. Vacuum interrupters required high technology for production.
  4. In the event of loss of vacuum, due to transient damage or failure, the entire interrupter is rendered useless. It cannot be required at site.
  5. For interrupter low magnetizing currents, in certain range, additional surge suppressors are required in parallel with phase of a VCB.
Related articles :
Sponsored links :

    about author

    hamada i'm hamada rageh electrical power engineer my talent to write articles about electrical engineering and i depend on google books site to write my articles

    التعليقات


    اتصل بنا

    إذا أعجبك محتوى مدونتنا نتمنى البقاء على تواصل دائم ، فقط قم بإدخال بريدك الإلكتروني للإشتراك في بريد المدونة السريع ليصلك جديد المدونة أولاً بأول ، كما يمكنك إرسال رساله بالضغط على الزر المجاور ...

    جميع الحقوق محفوظة

    your electrical home